pmisetech@gmail.com +86 133 2121 6666 FDA · CE · RoHS · SGS Certified
Pmise PE-02

HPT E-light

Pmise PE-02

  • Vacuum effectively reduces the density of melanin in epidermis and also hemoglobin in dermal papilla, which significantly weakens the E-light absorption of the epidermis. Compared with the ordinary E-light, it focus higher energy on target tissues and much safer
  • The nerve endings are hardly stimulated because of the epidermis barely absorbing any light. With the vacuum massage, the effect can be achieved painlessly and comfortably.
  • Compared with the ordinary E-light, OPT has already achieved excellent results. The unique vacuum function and unique SHR(Super Hair Removal) technology make the energy focus on target tissues so that the treatment sessions can be evidently reduced.

Overview

The Pmise PE-02 is a professional HPT E-light machine built for clinics, medical spas, and distributors who want one platform for pigment, vascular, skin rejuvenation, and hair reduction work. It pairs intense pulsed light with bipolar radiofrequency (RF) energy and adds Homogeneous Pulse Technology (HPT), so each flash delivers steady, repeatable output for daily treatment use.

Unlike single-energy IPL, the PE-02 combines optical and RF energy in one handpiece, which lets operators reach targets in the epidermis and dermis while keeping settings controlled. It ships with interchangeable filters and spot sizes so a single device covers several common aesthetic indications. As professional equipment, it is intended for use by trained operators who set energy to the patient's skin type and treatment goal.

The PE-02 belongs to Pmise's HPT E-light line. If you are comparing energy platforms, see our guide on HPT vs vacuum E-light vs IPL to understand where this model fits.

How It Works

E-light works by combining two energy sources. Broadband pulsed light targets chromophores in the skin, mainly melanin in pigment and hair, and haemoglobin in small vessels. That light is absorbed and converted to heat, which affects the intended target while the surrounding tissue is spared. This principle of matching light to a specific target follows the theory of selective photothermolysis described by Anderson and Parrish (1983).

The PE-02 adds bipolar radiofrequency on top of the optical pulse. RF energy is drawn to warmer, lower-impedance targets that the light has already preheated, so the two energies act together. In practice this means the light can often work at a more moderate setting because RF helps carry heat into the target, which supports treatment across a wider range of skin tones.

Homogeneous Pulse Technology is Pmise's contribution to pulse stability. HPT keeps each pulse's energy steady and regular so the output stays consistent with the value shown on the LCD, rather than drifting flash to flash. Pmise has applied semiconductor cooling to its light-based platforms since 2002, and the PE-02 uses semiconductor contact cooling at the handpiece to protect the skin surface during treatment. Selectable optical filters let the operator shape the wavelength band for pigment, vascular, or hair applications without changing handpieces.

Applications

The PE-02 is a multi-application platform suited to clinics that want to cover several popular services with one device. Typical uses include:

  • Wrinkle reduction and photo-rejuvenation
  • Overall skin rejuvenation and texture improvement
  • Hair reduction on suitable hair and skin combinations
  • Freckles and benign superficial pigmented lesions
  • Facial vascular lesions such as spider veins and broken capillaries
  • Support for acne-prone skin

It suits aesthetic clinics, medical spas, and distributors building a service menu around light and RF treatments. Suitability always depends on an operator's assessment of the individual's skin type, medical history, and contraindications before treatment.

Key Advantages

  • Dual optical plus bipolar RF energy in one handpiece, so light can run at controlled settings while RF carries heat into the target.
  • Homogeneous Pulse Technology keeps pulse energy steady and consistent with the LCD reading for predictable, repeatable sessions.
  • Semiconductor contact cooling helps protect the epidermis and improve comfort during treatment.
  • Selectable filters and multiple spot sizes cover pigment, vascular, rejuvenation, and hair applications on one platform.
  • No consumable optical cartridges for the E-light handpiece, which lowers ongoing cost of ownership.
  • Multi-application design consolidates several clinic services into a single reliable device.

Specification

Wavelength: 1064nm&532nm

 

Spot Diameter: 1mm-5mm continuously adjustable

 

Frequency: 1-5Hz

 

Pulse Width: 10-20ns

 

Pulse Energy: ≤200mj@1064nm;

        ≤100mj@523nm

   

RF

 

Cooling Temperature: 0℃-4℃

 

RF Frequency: 2.64MHz

 

RF Output Power: ≤120W

 

Cooling: Semiconductor Cooling

   

E-light

   

Flash Interval: 3s-5s continuously adjustable (step 1s)

 

Pulse Number: 2-10T continuously adjustable (step 1T)

 

1st Pulse Width: 0.1ms-10.0ms continuously adjustable (step 0.1ms)

 

1st Pulse Interval: 0.1ms-20.0ms continuously adjustable (step 0.1ms)

 

Sub-pulse Width: 0.1ms-20.0ms continuously adjustable (step 0.1ms)

Sub-pulse Interval: 0.1ms-10.0ms continuously adjustable (step 0.1ms)

 

Energy Density: ≤50J/cm² continuously adjustable (step1J/cm²)

 

Spot Size: 8mmX40mm

     

15mmX60mm (for hair removal)

Filters: 3 (skin rejuvenation, hair removal, vascular removal)

FAQ

What can the PE-02 treat?

It is a multi-application E-light platform used for skin rejuvenation, wrinkle and texture improvement, benign superficial pigment such as freckles, facial vascular lesions like broken capillaries, hair reduction, and support for acne-prone skin. The right indication and settings depend on a trained operator's assessment of each client's skin and goals.

Which skin types is it suitable for?

E-light's combined light and RF energy allows treatment across a range of skin tones, and Pmise has used semiconductor cooling on its platforms to reduce complications on darker skin. Even so, very dark or recently tanned skin needs extra caution. The operator should evaluate skin type and perform a test spot before a full session.

How many sessions are usually needed?

It depends on the indication, the individual, and their hair and skin colour. Pigment and vascular work often improve over a short series of visits, while hair reduction typically needs several spaced sessions because hair is only treatable during its active growth phase. No light-based system removes all hair permanently.

Do operators need training, and is there a warranty?

Yes. The PE-02 is professional equipment intended for trained operators who set energy to each client's skin and treatment plan. Pmise provides operating documentation and manufacturer warranty support. Contact us for current warranty terms, training materials, and parameter guidance for your market.